Development and manufacture of analytical equipment
ru | en

MetExpert: Portable X-Ray Fluorescence Analyzer

MetExpert: Portable X-Ray Fluorescence Analyzer

The MetExpert XRFA provides measurements of mass fraction of chemical elements in stainless, chromium and other steels, aluminum, magnesium, copper and other alloys and their products. The device can measure all chemical elements from sodium (Z=11) to americium (Z=95) in liquid, solid or powdery substances.

The analyzer has been used by military, police, customs, production and research organ-izations for materials identification and quality control, forensics, environmental monitoring (identification of toxic elements and chemical in liquids and soils) and other purposes.

Directions

Documents

Specifications

Feature
Value
Chemical elements atomic numbers range: Z=11(Na)…95(Am)
Number of elements identified simultaneously: 80
(Na, Mg, Al, Si, P, S, Cl, K, Ca, Sc, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, Ga, Ge, As, Se, Br, Rb, Sr, Y, Zr, Nb, Mo, Ru, Rh, Pd, Ag, Cd, In, Sn, Sb, Te, I, Cs, Ba, La, Ce, Pr, Nd, Sm, Eu, Gd, Tb, Dy, Ho, Er, Tm, Yb, Lu, Hf, Ta, W, Re, Os, Ir, Pt, Au, Hg, Tl, Pb, Bi, Po, At, Ac, Fr, Ra, Ac, Th, Pa, U, Np, Pu, Am)
Elements detection threshold (minimum mass fraction) for organic or mineral samples:
- From Na to Am from 5 ppm
Elements detection threshold (minimum mass fraction) for alloys:
- Na, Mg, Al, Si from 0.2 %
- From P to Mo from 0.02 %
- From Ag to Am from 0.05 %
Absolute error in the determination of the mass fraction of elements (“All elements” mode) in the ranges:
- From 0.2 to 1.0 % ± 0.10 %
- From 1.0 to 10.0 % ± 0.50 %
- From 10.0 to 100.0 % ± 0.70 %
Absolute error in the determination of the mass fraction of elements Ti, V, Cr, Mn, Co, Ni, Mo, W (“Nickel and Stainless Steels” mode) in the ranges:
- From 1.0 to 40.0 % ± 0.50 %
- From 40.0 to 80.0 % ± 0.70 %
Warm-up time, not more than: 5 minutes
Measuring time (selected by the operator depending on the type of sample and/or required accuracy): from 5 to 300 seconds
Power consumption: up to 35W
Continuous battery life: up to 8 hours
The equivalent dose rate in normal operating conditions of the not more than 1.0 µSv/h
analyzer at a distance of 0.1 m from the surface at any accessible point:
Operation conditions: temperature from -30 to + 45°C, relative humidity from 0 to 95%
Dimensions (L×W×H): 200×95×260 mm
Weight: 2.0 kg

Main Advantages

  • Identification of all chemical elements from sodium to americium in the base set
  • The accuracy in determining of the mass concentration of elements that is not accessible for most available handheld XRFA
  • Significantly higher reliability, stability and durability of the X-ray machine through the use of schemes with a massive anode
  • Best performance in the analysis of the full range of elements in all types of materials without replaceable filters

← Back